Structural Drawing Review
Read a structural set against the architectural, from the architect's side
Once installed, Claude loads it on its own when your conversation matches. You can also call it directly with /structural-drawing-review.
Install just this one
npx archtmpl@latest --skill structural-drawing-review --globalFirst time? The whole install, step by step
- Open Claude Code — the terminal version or the desktop app, either one.
- In a terminal, paste the line above and press Enter. In the app, paste it into the chat and ask Claude to run it.
- Restart Claude Code. That's the whole install.
Set up plugins for me: run `claude plugin marketplace add https://archaiflow.com/plugins/marketplace.json` and then `claude plugin install structural-drawing-review@archaiflow`Paste into the Code tab (not Chat or Cowork) and approve when Claude asks. The third-party marketplace it mentions is this site. Windows may ask to install Git once.
What this skill does
Structural Drawing Review
The architect is not going to check the engineering and should not try. What the architect has to check is the other thing, and nobody else does it: whether the frame that was designed fits the building that was drawn, and whether the structural set still assumes a plan that has moved.
Workflow
Step 1. Establish what you are comparing
Ask, in one message:
- What revision is each set, and was the structural set drawn on the current architectural background?
- What phase, and what is the structural set issued for?
- Do you have the general notes and the drawings they reference?
- Has the geotechnical report been reviewed, and does the structural set cite it?
- What is fixed architecturally that the structure has to work around: ceiling heights, clear spans, openings, a facade module?
A structural set drawn on a superseded architectural background is the most common and the most expensive finding, and it is answered by a question rather than by reading drawings.
Step 2. Compare grids, levels and datums first
Nothing after this is meaningful if these disagree:
- Grid lines: same designations, same spacing, same origin on both sets.
- Levels: same names, same elevations, same datum.
- Whether structural levels are top of steel, top of slab, or finished floor, and whether the architectural set means the same thing by the same name. This one difference produces more errors than any other.
- Building outline and any relationship to the property line.
Step 3. Find the structure that lands in the architecture
Walk the plans together and report every conflict:
| Location | Structure | Architecture | Conflict | Both values |
|---|
- Columns in rooms, in corridors, in unit layouts, in parking bays, in the middle of a door.
- Braced frames and shear walls where the plan wants an opening or a glass line.
- Transfer structure, and what its depth does to the floor below.
- Beams crossing where the ceiling has to be highest.
- Foundations conflicting with a lift pit, a shaft, a sump, or a below-grade wall.
- Slab edges, steps and depressions against the architectural floor finishes.
- Anything landing in the working clearance of an electrical room or the service space of a plant room.
Step 4. Work the vertical dimension, which is where ceilings are lost
Structural depth is the constraint the architecture feels most:
- Deepest member in each area, against the floor-to-floor and the required clear height.
- Where members cross, and what the depth is at the crossing.
- Where services have to pass under, over, or through structure, and whether
penetrations through members are shown and permitted. Point at
mep-review. - Slab thickness and any topping, against the floor build-up the architecture assumes.
- Roof structure against the roof build-up and the drainage falls.
Report the clear height available in each area against what the architecture requires, as two figures.
Step 5. Find what has been deferred, and to whom
The most valuable pass and the easiest to skip. Structural sets defer work routinely and legitimately, and the deferral has to land on somebody:
- Anything marked delegated design, design-build, or by others: connections, cold-formed framing, stairs and railings, curtain wall attachment, precast, joists, canopies, elevator rail loads.
- For each: who designs it, who reviews it, whose seal, when it is submitted, and is it in anybody's fee?
- Anything marked to be confirmed, by supplier, or subject to shop drawings.
- Whether the specification carries the delegated design requirements the drawings assume.
A delegated item with no owner is a gap the architect stands in.
Step 6. Report
| # | Finding | Structural says | Architectural says | Kind |
|---|
Kind is conflict, gap, duplicate, or deferred. Report both values on
every conflict and rule on none.
Then, in order:
- Grid, level and datum disagreements, first. Everything else waits on them.
- Conflicts affecting clear height or a fixed architectural dimension.
- Deferred items with no owner.
- What could not be checked and why.
Close by saying the engineering was not reviewed.
Step 7. Save, if asked
Ask whether to write the review to a file and where.
Rules
- Never check or comment on the engineering.
- Never supply a span, a depth, or a load.
- Compare grids, levels and datums before anything else, and stop if they disagree.
- Establish what each set means by a level name.
- Report both values on every conflict and decide neither.
- List every deferred item with who owns it, or flag that nobody does.
- Say what was not supplied and therefore not reviewed.
Anti-patterns
- Checking whether a beam is big enough.
- Comparing sets drawn on different architectural backgrounds without saying so.
- Assuming top of steel and finished floor mean the same thing.
- Reporting a column conflict and choosing which drawing is right.
- Treating a delegated design note as somebody else's problem.
- Checking plan conflicts and not clear heights.
- Reviewing without the general notes.
Resources
None. This skill is one file. Output is written directly at the path you choose.
What it does not check
What this does. Compares the structural set against the architectural set and reports the disagreements, the spatial conflicts, and the work the structural drawings have deferred to somebody who may not know it.
What this does not do.
- It does not check the engineering. Not loads, not spans, not member sizes, not connections, not lateral systems, not foundations. Those are the engineer's, they are sealed, and second-guessing them from an architect's chair is both useless and unwise.
- It carries no values. No spans, no depths, no loads, no code requirements.
- It does not cover MEP coordination.
mep-reviewreads that set, andpenetration-reviewcovers holes through structure. - It does not read the geotechnical report.
geotech-report-reviewdoes, and the structural set should be consistent with it. - It does not replace the structural engineer or the Architect of Record.
What you need before starting. Both sets, at stated revisions. The architectural background the structural set was drawn on. The general notes and the specification sections referenced. The geotechnical report, if foundations are in scope.
Files it puts on your disk